AM2302 Temperature And Humidity Sensor
AM2302 overview
AM2302 output calibrated digital signal. It applies exclusive digital-signal-collecting-technique and humidity sensing technology, assuring its reliability and stability. Its sensing elements are connected to an 8-bit single-chip computer. Every sensor of this model is temperature compensated and calibrated in an accurate calibration chamber and the calibration coefficient is saved in the type of program in OTP memory when the sensor is detecting, it will cite the coefficient from memory. Small size & low consumption & long transmission distance(100m) enable AM2302 to be suited for all kinds of harsh application occasions. Single-row packaged with four pins, making the connection very convenient.

Key specifications
Model
AM2302
Power supply
3.3-5.5V DC
Output signal
digital signal via a 1-wire bus
Sensing element
Polymer humidity capacitor
Operating range
humidity 0-100%RH; temperature -40~80Celsius
Accuracy
humidity +-2%RH(Max +-5%RH); temperature +-0.5Celsius
Resolution or sensitivity
humidity 0.1%RH; temperature 0.1Celsius
Repeatability
humidity +-1%RH; temperature +-0.2Celsius
Datasheet
digitalhumidityandtemperaturesensoram2302.pdf
Format PDFSize 407 KBLanguage EN
Third-party / unverified source
AM2302 features
- High precision
- Capacitive type
- Full-range temperature compensated
- Relative humidity and temperature measurement
- Calibrated digital signal
- Outstanding long-term stability
- Long transmission distance, up to 100 meters
- Low power consumption
- 4 pins packaged and fully interchangeable
AM2302 pinout
AM2302 specifications
| Model | AM2302 |
|---|---|
| Power supply | 3.3-5.5V DC |
| Output signal | digital signal via a 1-wire bus |
| Sensing element | Polymer humidity capacitor |
| Operating range | humidity 0-100%RH; temperature -40~80Celsius |
| Accuracy | humidity +-2%RH(Max +-5%RH); temperature +-0.5Celsius |
| Resolution or sensitivity | humidity 0.1%RH; temperature 0.1Celsius |
| Repeatability | humidity +-1%RH; temperature +-0.2Celsius |
| Humidity hysteresis | +-0.3%RH |
| Long-term Stability | +-0.5%RH/year |
| Interchangeability | fully interchangeable |
AM2302 applications
- Environmental monitoring systems: The AM2302 sensor can be used in environmental monitoring applications to measure temperature and humidity levels in real time. It is commonly employed in weather stations, greenhouses, and indoor climate control systems.
- HVAC systems: Heating, ventilation, and air conditioning (HVAC) systems rely on accurate temperature and humidity measurements to maintain optimal indoor conditions. The AM2302 sensor can be integrated into these systems to provide precise data for temperature and humidity control.
- Agriculture and horticulture: The sensor can be utilized in agricultural and horticultural settings to monitor temperature and humidity levels in crop cultivation areas. This information helps farmers and growers create suitable conditions for plant growth and optimize irrigation strategies.
More about AM2302
Pinout
| 1 | Vcc | Power supply 3.5V to 5.5V |
| 2 | Data | Outputs both Temperature and Humidity through serial Data |
| 3 | NC | No Connection and hence not used |
| 4 | Ground | Connected to the ground of the circuit |

Comments 0
Leave a comment