Skip to content
Trademarks and datasheets are the property of their respective owners

MQ131 Ozone Gas Sensor Module

Published 5,862 views
Series MQ gas sensors
MQ131 Ozone Gas Sensor Module Datasheet

MQ131 overview

MQ131 Ozone gas sensor module belongs to the MQ gas sensor family infamous for their use in the early detection and warning of toxic concentrations of harmful gases in a closeby vicinity. MQ131 sensor possesses lower conductivity in clean air and higher conductivity when the ozone concentration rises. The core sensing element in MQ131 sensors is SnO2 which allows for quick detection of the harmful concentration of Ozone gas. MQ131 sensor also possesses strong sensitivity to strong oxides such as Cl₂, NO₂ &, etc. It responds oppositely to organic interference gases. The sensing range is 10 - 1000ppm. The sensor is easily interfaceable with almost every MCU such as Arduino Uno, ESP32, NodeMCU, etc.

MQ131 gas sensor is widely used in domestic ozone concentration alarms, industrial ozone concentration alarms, and portable ozone concentration detectors. The module also features ESD protection and overvoltage protection capabilities.

MQ131 Ozone Gas Sensor Module-2

Key specifications

Sensor Type
Semiconductor
Standard Encapsulation
Bakelite (Black Bakelite)
Detection Gas
Ozone
Concentration
10-1000ppm
Loop Voltage Vc
≤24V DC
Heater Voltage VH
5.0V±0.2V AC or DC
Load Resistance
Adjustable
Sensitivity S
Rs(in air)/Rs(in 50ppm O3)≥3

Datasheet

mq131.pdf
Format PDFSize 159 KBLanguage EN
Third-party / unverified source

MQ131 features

  • High Sensitivity to Ozone and heavy oxide gases.
  • The operating Voltage is +5V
  • Can be used to detect LPG or Butane gas
  • Analog output voltage: 0V to 5V
  • Digital Output Voltage: 0V or 5V (TTL Logic)
  • ESD protection
  • Overvoltage protection
  • Preheat duration 20 seconds
  • Simple drive circuit
  • Fast response
  • Stable and Long life

MQ131 pinout

MQ131 pinout diagram
PinNameDescription
1VCCThis pin powers the module, typically the operating voltage is +5V
2GNDUsed to connect the module to the system ground
3DOYou can also use this sensor to get digital output from this pin, by setting a threshold value using the potentiometer
4AOThis pin outputs 0-5V analog voltage based on the intensity of the gas.

MQ131 specifications

Sensor Type Semiconductor
Standard Encapsulation Bakelite (Black Bakelite)
Detection Gas Ozone
Concentration 10-1000ppm
Loop Voltage Vc ≤24V DC
Heater Voltage VH 5.0V±0.2V AC or DC
Load Resistance Adjustable
Sensitivity S Rs(in air)/Rs(in 50ppm O3)≥3
Slope (α) (R50ppm/R10ppm O3)
Tem. Humidity 20℃±2℃;65%±5%RH
Preheat time Over Forty-Eight hours
Sensing Resistance Rs 50KΩ-500KΩ(in 50ppm O3)

MQ131 applications

  • Used in gas leakage detecting equipment for Research labs and industry. They are suitable for detecting O3 and high concentrations of heavy oxide gases.
  • Industrial Ozone gas detector
  • Portable Ozone concentration overload Detector

More about MQ131

MQ131 datasheet PDF preview

PDF · 159 KB