Skip to content
Trademarks and datasheets are the property of their respective owners

MH-Z19B Co2 10000ppm Sensor Module

Published Updated 10 views

MH-Z19B overview

This 10000ppm MH-Z19B co2 Sensor detects carbon dioxide Co2. 10000ppm MH-Z19B CO2 sensor has high sensitivity, high resolution, and low power consumption. MH-Z19 carbon dioxide gas sensor (hereinafter referred to as the sensor) is a generic type, small sensor, using the nondispersive infrared (NDIR) principle to detect the air in the presence of CO2, with good selectivity and no oxygen dependence and long service life. Built-in temperature compensation, with digital output and waveform output, is easy to use. The sensor is a high-performance sensor that is combined with mature infrared absorption gas detection technology and precise optical path design and excellent circuit design. Sensor characteristics High sensitivity, high resolution, low power consumption Provide UART, PWM waveform, such as a variety of output mode Temperature compensation, excellent linear output Excellent stability Long service life Anti-water vapor interference, not poisoning Main application Can be widely used in HVAC refrigeration and indoor air quality monitoring. 

Key specifications

Operating voltage
4.5 ~ 5.5V DC
Response time
T90 <120s
Operating temperature
0 ~ 50 ℃
Operating humidity
0 ~ 95% RH (non-condensing)
Detection gas
carbon dioxide
Product Model
MH-Z19B
Average current
<60mA ( 5V supply)
Peak current
150 mA (5V supply)

Datasheet

mh-z19b-co2-ver1-0.pdf
Format PDFSize 710 KBLanguage EN
Third-party / unverified source

MH-Z19B features

  • High sensitivity, high resolution, low power consumption
  • Provide UART, PWM waveform, and other output methods
  • Temperature compensation, excellent linear output
  • Excellent stability
  • Long life
  • Water vapor interference, not poisoning

MH-Z19B pinout

NameDescription
VinInput Voltage
GNDGround Pin
VoOutput Voltage
PWMPulse Width Modulation
HDHD(Zero Calibration)
RXReceiver Pin
TXTransmitter Pin

MH-Z19B specifications

Operating voltage 4.5 ~ 5.5V DC
Response time T90 <120s
Operating temperature 0 ~ 50 ℃
Operating humidity 0 ~ 95% RH (non-condensing)
Detection gas carbon dioxide
Product Model MH-Z19B
Average current <60mA ( 5V supply)
Peak current 150 mA (5V supply)
Interface level 3.3V
Measurement range 0 ~ 1% VOL range optional
Output signals UART, PWM, analog output (default 0.4 ~ 2V)

MH-Z19B datasheet PDF preview